Insulating single-skin construction

Print this page Click here to tip a friend about this page!

A fast-track, simple and reliable form of construction. Detailing at openings is of vital importance to avoid moisture tracking around seals to the inner face. Simple traditional sealants are of concern to designers as there is a very short distance between the elements and the substrate at openings.


Problem

Single-skin solid wall construction may need relatively thick materials to provide thermal requirements, thereby increasing the building footprint.

The masonry available to provide thermal resistance at reasonable thickness for single-skin construction often needs a protective and decorative cladding.

Without careful detailing at openings water can track around windows and door frames etc. bypassing seals at openings.

Good quality and reliable seals are paramount. Simple gun-applied sealants used with cavity construction are often poorly applied. If they fail for whatever reason with single-skin construction, the construction is immediately exposed.

Solution

Use weber.therm XM and weber.therm FT system

weber.therm XM and the weatherseal unit from the weber.therm FT components insulate the structure while providing robust multi level defence to water ingress at openings.


Weber products

Printable version